Sony F65: Error Messages and causes
If the battery voltage drops or an error is detected when power is applied or during operation, the corresponding indicator lights up/flashes and a message appears on the subdisplay. The error details are displayed in the selfdiagnostics on settings page 3 on the subdisplay and in the viewfinder.
Warnings and error messages occurring on the SR-R4 are also displayed in the self-diagnostics field.
If the battery voltage drops or an error is detected when power is applied or during operation, the corresponding indicator lights up/flashes and a message appears on the subdisplay. The error details are displayed in the selfdiagnostics on settings page 3 on the subdisplay and in the viewfinder.
Warnings and error messages occurring on the SR-R4 are also displayed in the self-diagnostics field.
A
message prompt is also displayed in the viewfinder/ monitor to execute the APR
function if a defect is detected in the image sensor when the camera powers on
or if the APR function is not executed regularly. If prompted, execute
Automatic Pixel Noise Reduction
Indicator
|
Subdisplay
|
Self
diagnostics field indication
|
Meaning
|
REC:
Flashing red
|
12
V power supply voltage indicator flashing
|
12V
Battery (Near End)
|
The
voltage of the 12 V power supply has fallen to the
Near End value setting. |
REC:
Flashing red rapidly
|
12
V power supply voltage indicator flashing rapidly
|
12V
Battery (End)
|
The
voltage of the 12 V power supply has fallen to the
End value setting. |
REC:
Flashing red
|
24
V power supply voltage indicator flashing
|
24V
Battery (Near End)
|
The
voltage of the 24 V power supply has fallen to the
Near End value setting. |
REC:
Flashing red rapidly
|
24
V power supply voltage indicator flashing rapidly
|
24V
Battery (End)
|
The
voltage of the 24 V power supply has fallen to the
End value setting. |
REC:
Flashing when synced with SR-R4.
|
Media
remaining indicator flashing
|
Media
Remain (Near End)
|
The
remaining media on the SR-R4 has reduced to the
Near End value setting. |
REC:
Flashing when synced with SR-R4.
|
Media
remaining indicator flashing rapidly
|
Media
Remain (End)
|
The
remaining media on the SR-R4 has reduced to the
End value setting. |
DIAGNOSIS:
Flashing red rapidly
|
Displays
same message as self diagnostics field in a dialog.
|
Temperature
NG!
Shutdown Camera |
The
internal camera temperature has reached its limit.
Turn off the camera power supply. |
DIAGNOSIS:
Flashing red rapidly
|
Fan1
NG!
|
Fan1
NG!
|
Fan 1 near the top panel stopped. |
DIAGNOSIS:
Flashing red rapidly
|
Fan2
NG!
|
Fan2
NG!
|
Fan 2 near the top panel stopped. |
DIAGNOSIS:
Flashing red
|
Sync
Error
|
Sync
Error
|
A
sync error occurred.
|
DIAGNOSIS:
Lit red DOCK: Lit yellow
|
Optical
Level Care
|
Optical
Level Care
|
The optical level of the Recorder connector has reduced to caution level. Clean the Recorder connector or replace the optical module. |
DIAGNOSIS:
Lit red DOCK: Lit red
|
Optical
Level NG
|
Optical
Level NG
|
A
light reception error occurred with the Recorder
connector. Immediately, clean the Recorder connector or replace the optical module. |
DIAGNOSIS:
Lit red DOCK: Not lit
|
Optical
Level No Input
|
Optical
Level No Input
|
No
signal is input on the Recorder connector.
|
DIAGNOSIS:
Lit red
|
CRCC
Error occurred
|
CRCC
Error occurred
|
A
Cyclic Redundancy Check Code (CRCC) error
occurred with the Recorder connector. Clean the recorder connector. |
Mounting
the SR-R4
Always
turn off the camera power supply when mounting the SR-R4.
The
recorder connector for connecting the SR-R4 is an optical connector. Attach the
connector cap on the optical connector when not connected to an SR-R4 to
protect the connector. After removing the cap, store it in the position shown
in the following figure for safekeeping.
When
mounting the SR-R4, fix the camera head on a tripod in advance to keep the
camera head stable.
When
the camera is used with the SR-R4 docked, make sure that the camera is securely
fixed and stable so that it will not fall over.
Attaching
a Filter
1. Place the filter template (metallic disc) on the gel filter, then trim the filter around the edge of the filter template.
2. Remove the ring from the filter holder, place the filter on the ring, and then attach the holder.
1. Place the filter template (metallic disc) on the gel filter, then trim the filter around the edge of the filter template.
2. Remove the ring from the filter holder, place the filter on the ring, and then attach the holder.
3. Align
the protrusion on the mounting tool with the notch on the filter holder, then
insert the holder into the tool.
4. Align
the notch on the filter mount with the protrusion on the filter holder, insert
the mounting tool onto the filter mount, and then turn clockwise until it
clicks into place.
5. Pull
the mounting tool straight off. The mounting tool separates from the camera,
and the filter is mounted in place.
To
remove the filter
1. Align the protrusion on the mounting tool with the notch on the filter holder, then press the tool onto the filter mount. Press the tool until it clicks into place.
1. Align the protrusion on the mounting tool with the notch on the filter holder, then press the tool onto the filter mount. Press the tool until it clicks into place.
2. Rotate
the mounting tool counterclockwise, then lift the tool off the camera.
The
filter holder is removed with the mounting tool.