Sony 3D DLP projector – Sony VPL-HW30ES - HW30AES – How to replace the projector lamp – How to remove and clean the airlifter - How to rest the lamp hour

Sony VPL-HW30ES - HW30AES 
How to replace the Lamp
1. Turn off the projector and unplug the AC power cord.
2. When setting the projector on a flat surface such as a desk etc., put a cloth to prevent the surface from being scratched. Reverse the projector as illustrated, then place it on the cloth.
3. Loosen the screw on the lamp cover with a Philips screwdriver, and then open the lamp cover.
4. Loosen the 3 screws on the lamp with the Phillips screwdriver. Hold up the handle, then pull the lamp straight out.
5. Hold the handle of the new lamp and push it in securely until it reaches the end, and then tighten the 3 screws.
6. Close the lamp cover, and then tighten the screws.
Air Filter Cleaning 
1. Remove the filter holder.
2. Remove the air filter.
3. Attach the new air filter so that it fits into the each claws (10 positions) on the filter holder.
Attach the air filter aligning it with the shape of the filter holder. Also, do not touch the fan after removing the air filter that is set deep inside the projector.
4. Attach the filter holder.
The projector will not turn on unless the filter holder is securely closed.
5. Wipe dust off the ventilation holes (intake) with a soft cloth.
6. Place the project back on its original position.
7. Turn on the projector, then select the desired setting item on the Setup menu. The menu screen will  appeared.
8. Select “Yes”.

Do not put your hands into the lamp replacement slot, and do not allow any liquid or other objects into the slot to avoid electrical shock or fire.