Monday 19 February 2018

Sharp LC-60EQ10U - How to enter service mode, adjustments, public mode, factory settings and more

ADJUSTMENT PROCEDURE
The adjustment values are set to the optimum conditions at the factory before shipping. If a value should become improper or an adjustment is required due to part replacement, make an adjustment according to the following procedure.
After replacement of any PWB unit and/or IC for repair, please note the following.
• When replacing the following units, make sure to prepare the new units loaded with updated software.
MAIN Unit: DKEYMG381FM01, DKEYMG382FM01
LC-60/70EQ10U
LC-60/70SQ10U
LC-60/70SQ15U
LC-60/70SQ17U
LC-60/70TQ15U
LC-60/70UQ17U
When replacing the LCD control PWB, perform the VCOM adjustment.
Upgrading of each microprocessor software
CAUTION: Never “POWER OFF” the unit when software upgrade is ongoing. Otherwise the system may be damaged beyond recovery.
Software version upgrade
The model employs the following software.
• Main software (please use a software version after ASTN_UQ17U_xxx.USB).
• Monitor microprocessor software (please use a software version after ASTNMxxx.SMB.)
The main software, monitor microprocessor software can be upgraded by using a general-purpose USB Memory.
The followings are the procedures for upgrading, explained separately for the main software, monitor microprocessor software.
Main software version upgrade
Get ready before you start
• USB Memory of 128MB or higher capacity.
• PC running on Windows 98/98SE/ME/2000/XP operating system.
• USB Memory reader/writer or PC with a USB port.
• The file system of a USB memory is FAT. (FAT32 supports)
• Use the USB memory without other functions. (lock and memory reader...etc)
Preparations
To upgrade the main software, it is necessary to get ready the USB Memory for version upgrade before you start.
Follow the steps below and create the USB Memory for version upgrade.
1. Copy the file ASTN_UQ17U_xxx.USB for version upgrade to the root directory (folder) of the USB Memory.
NOTE: In the USB Memory drive, do not store other folders or unrelated files, or more than one file for version upgrade.
Now the USB Memory for version upgrade is ready.
How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade into the service socket.
3. Plug in the AC cord with power button pressed down.
4. After 5 seconds, unpress the power button.
5. After the unit startup, the system upgrade screen as shown below within 20-40 seconds.
6. Even a single failure in the process will trigger the upgrade failure screen.
NOTE: In the event of a failure, repeat the upgrade process. If the process repeatedly fails, it is likely that the hardware need fixing.
7. Upon completion of the whole process, the upgrade success screen as shown below appears. You can check the new software version on this screen. The version information appears after the upgrade is complete.
8. Unplug the AC cord and remove the USB Memory for version upgrade.
9. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the main software version information.
Monitor microprocessor software version upgrade
Create the USB memory for monitor microprocessor software version upgrade in the same manner as explained in the “Main software version upgrade”.
Copy the file ASTN_UQ17U_xxx.USB and ASTNMxxx.SMB. (named temporarily) for monitor microprocessor software version upgrade to the USB memory.
How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade into the service socket.
3. Plug in the AC cord with power button pressed down.
4. After 5 seconds, unpress the power button.
CAUTION: • The moment this operation is done, the upgrading of the monitor microprocessor software starts. While the upgrade is ongoing, never power off the unit. Otherwise the upgrade will fail and the system may be serious damaged beyond recovery (inability to start).
• After the monitor microprocessor software is upgraded, also perform the ‘Industry Init’.
5. After the unit startup, the upgrade starts. The power led will blink continuously. Also, an upgrade screen will be shown during a minor upgrade.
6. If the upgrade fails, power led will stop blinking. Also, the upgrade failure screen will be shown.
NOTE: In the event of a transient failure, upgrade will be automatically retried up to three times. If the process repeatedly fails, hardware may be the cause.
7. The upgrade success screen will be shown.
8. Unplug the AC cord and remove the USB Memory for version upgrade.
9. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the monitor microprocessor software version information and panel size information.
Entering and exiting the adjustment process mode
1) Before entering the adjustment process mode, the AV position RESET in the video adjustment menu.
2) While holding down the “VOL (–)” and “INPUT” keys at a time, plug in the AC cord of the main unit to turn on the power.
The letter “<K>” appears on the screen.
3) Next, hold down the “VOL (–)” and “CH (Dn )” keys at a time.
(The “VOL (–)” and “CH (Dn )” keys should be pressed and held until the display appears.)
Multiple lines of blue characters appearing on the display indicate that the unit is now in the adjustment process mode.
When you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4) To exit the adjustment process mode after the adjustment is done, unplug the AC cord from the outlet to make a forced shutdown. (When the power was turned off with the remote controller, once unplug the AC cord and plug it again. In this case, wait 10 seconds or so before plugging.)
CAUTION: Use due care in handling the information described here lest your users should know how to enter the adjustment process mode. If the settings are tampered in this mode, unrecoverable system damage may result.
Remote controller key operation and description of display in adjustment process mode and service mode display descriptions.
Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal is available.
Key writing
EDID writing (Main PWB: QPWBXG381WJ**/QPWBXG382WJ**)
1. Write the EDID key data on IC3103 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
MAC key writing (MAIN PWB: QPWBXG381WJ**/QPWBXG382WJ**)
1. Write the NETFLIX/WMDRM key data on IC3103 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
NETFLIX/WV(RoxioNow)&WMDRM key writing HDCP 2.2(Miracast) (MAIN PWB: QPWBXG381WJ**/QPWBXG382WJ**)
1. Write the wide vine key data on IC3103 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
NOTE: For EDID of the analog RGB (DSUB 15pin), write the data on the process menu just like HDMI.
* Update Logic Serial No. writing (MAIN PWB: QPWBXG381WJ**/QPWBXG382WJ**)
Factory setting
After completing the factory setting, pull out the AC cord to complete the setting.
CAUTION: Do not turn on the power after completing the factory setting. If the power is turned on, configure the factory setting again.
Software version
1. Main microprocessor
ASTN_UQ17U_xxx.USB
ASTN_UQ17U_xxx.DAT
ASTN_UQ17U_xxx_CHK.USB
ASTN_UQ17U_xxxxxxxx.PCC
2. Monitor microprocessor
ASTNMxxx.SMB
3. T-CON ROM
APRICOT_****************.ROM
Writing the inch and model name onto EEPROM
1. Enter the adjustment process mode.
2. Point the cursor to [MODEL NAME] (Page 28/28).
3. Select "EQ10U" or "SQ10U" or “SQ15U” or “SQ17U”or “TQ15U”, and press [Enter] key.
4. "OK" is displayed.
5. Point the cursor to [PANEL SIZE] (Page 28/28).
6. Select "60" or "70" or "80" and press [Enter] key.
7. Moments later image is displayed.
8. Turn off power
9. Turn on power.
Check MIRACAST HDCP (EQ/SQ/TQ/UQ models)
After changing to New Main board , change "Model and Panel Size" and write "Serial Number", then please check if MIRACAST HDCP is written or
not.
1) Models which MIRACAST HDCP is needed
EQ/SQ/TQ/UQ models should have MIRACAST HDCP written because they are models which have miracast feature.
Please check after changing main unit and make sure that MIRACAST HDCP is written.
How to check
1. Enter the adjustment process mode.
2. Look at MIRACAST HDCP on the 1st page.
Example: LC-60EQ10U
CAUTION: When reusing the main units taken from other TV sets, be aware not to use main units taken from TV sets of LE642UA/LE650UA/LE657UA models.
LE642UA/LE650UA/LE657UA models are shipped out with MIRACAST HDCP not written when production.)
Example: LC-60LE650UA
How to White Balance Data Copy
NOTE: This is only available when it's possible to enter the adjust process mode.
Get ready before you start
• USB Memory of 128MB or higher capacity.
• PC running on Windows 98/98SE/ME/2000/XP operating system.
• USB Memory reader/writer or PC with a USB port.
• The file system of a USB memory is FAT. (FAT32 supports)
• Use the USB memory without other functions. (lock and memory reader...etc)
• Use the USB memory without other files.
Before change Main Board
Enter the adjustment process mode and go to page where it has "USB BACKUP".
Insert the USB Memory into the service socket.
Press Enter, return "Backup OK"
Written AQUOS_DATA.dat into USB Memory.
After change Main Board
Entering the adjustment process mode Enter the adjustment process mode and go to page where it has "USB RESTORE".
(Same page as where "USB BACKUP" was.)
Insert the USB Memory written AQUOS_DATA.dat into the service socket.
Press Enter
After about 7 second , return "Restore OK"
PUBLIC MODE SETTING PROCEDURE
How to start Public Mode
• There are the following two ways to get the public mode setup screen displayed.
In the adjustment process mode, turn on “PUBLIC MODE”. Also press the “CH ( )” and “VOL (+)” keys on the set at once and turn on the power.
1) Press the “INPUT” and “VOL (+)” keys on the set at once and turn on the power.
2) Get the password input screen displayed.
3) The 3-digit password is now verified.
The password [0] [2] [7] provides for the public mode screen. (This screen comes on with whatever adjustment process settings.)
With any other passwords, the screen changes to the normal mode.
How to exit Public Mode
There are the following ways to quit the public mode setup screen.
• Turn off “PUBLIC MODE” in the adjustment process mode. ( ) ← This way alone is not for quitting the setup screen, but for quitting the mode itself.
• Turn off the power with the “POWER” key. ( )
• Select “EXECUTE”. ( )
 “PUBLIC MODE” stays on in the adjustment process mode.
 The settings will be back to the factory ones.
Public Mode Menu
The guidance is not displayed on screen.
Setup procedure
• To move the cursor up and down, use the “cursor UP/DOWN” key (remote controller) and “CH (Up )/(Dn )” key (remote controller and set).
• To change the settings, use the “cursor RIGHT/LEFT” key (remote controller) and “VOL (+)/(–)” key (remote controller and set).
• To save new settings, keep the cursor at “EXECUTE” and use “ENTER” key (remote controller and set)
How to use USB clone
This is the function that copying the one TV's user setting to other TVs or copying previous user setting to itself.(Only same series.)
1. Insert the USB memory to TV.
2. Insert AC code of TV with pushing the “INPUT” and “Vol+” keys which are on the tact key.
3. Enter the password by using R/C. The password is “027”.
4. Select “COPY MODE”.
5. The follow guide is displayed. Then select the “TV→USB [Start]”.
6. Follow guide is displayed when it is finished, then select "Reset" . TV will restart.
7. Insert the USB which has the data from TV to another TV or itself.
8. Insert AC code of the TV with pushing the "INPUT" and "Vol+" keys which are on the tact key.
9. Select “COPY MODE”.
10. The guide is displayed. Then select the “USB→TV [Start]”.
11. Follow guide is displayed when it is finished, then select "Reset" . TV will restart.
12. Confirm the user setting is copied.

LG 32LK610BPUA, LG 32LK610BBUA LCD TVs – How to upgrade the software, fault checking method

  Software update procedure USB (1) Insert the USB memory Stick to the USB port (2) Automatically detect the SW Version and show the bel...