EAY62609601-LG 42PA4500-ZF SMPS
Protection over Current, Under Voltage
and Over Voltage conditions
The OCP test of STBY,
5.2V, M5V and 17V should setup current rise slew rate greater than 3.6A/S.
This Power Supply has above-mentioned protections.
The time for short shall be less than 10sec.
PSU should be shut down by under voltage protection when short circuit test
PSU should be wake up normally when AC off-on / Relay off-on / protection
removal
Short circuit protection between different output terminals is not considered.
Trip point for over voltage indicates the operating point when the output
voltage slowly increases.
AC Over-voltage Test
1) Over voltage shall
test 315Vac~340Vac , Protection should be occur.
2) No fire, shock hazard or explosion shall occur.
Function of protection
Input Output PIN assignment
Schematic
BBK LEM1961 POWER BOARD schematic