How to enter the service mode of LG Flatron L1733TR, L1933TR color monitors, EDID data writing - Schematic

 

Video Controller Part.
This part amplifies the level of video signal for the digital conversion and converts from the analog video signal to the
digital video signal using a pixel clock.
The pixel clock for each mode is generated by the PLL.
The range of the pixel clock is from 25MHz to 135MHz.
This part consists of the Scaler, ADC convertor, TMDS receiver and LVDS transmitter.
The Scaler gets the video signal converted analog to digital, interpolates input to 1280 X 1024 resolution signal and
outputs 8-bit R, G, B signal to transmitter.

Power Part.
This part consists of the one 3.3V, and one 1.8V regulators to convert power which is provided 5V in Power board.
12V is provided for inverter, 5V is provided for LCD panel.
Also, 5V is converted 3.3V and 1.8V by regulator. Converted power is provided for IC in the main board.
The inverter converts from DC12V to AC 700Vrms and operates back-light lamps of module.

MICOM Part.
This part is include video controller part. And this part consists of EEPROM IC which stores control data, Reset IC and
the Micom.
The Micom distinguishes polarity and frequency of the H/V sync are supplied from signal cable.
The controlled data of each modes is stored in EEPROM.

SERVICE mode

Turn off the power switch at the front side of the display.

Wait for about 5 seconds and press MENU, POWER switch with 1 second interval.

The SVC OSD menu contains additional menus that the User OSD menu as described below.

Auto Color : W/B balance and Automatically sets the gain and offset value.

NVRAM INIT : EEPROM initialize.(24C08)

CLEAR ETI : To initialize using time.
AGING : Select Aging mode(on/off).
R/G/B-9300K : Allows you to set the R/G/B-9300K value manually.
R/G/B-6500K : Allows you to set the R/G/B-6500K value manually.
R/G/B-Offset : Allows you to set the R/G/B-Offset value manually.(Analog Only)
R/G/B-Gain : Allows you to set the R/G/B-Gain value manually.(Analog Only)
MODULE : To select applied module.

ADJUSTMENT To apply the MSTAR Chip.

Operating System: MS Windows 98, 2000, XP
Port Setup: Windows 98 => Don’t need setup
Windows 2000, XP => Need to Port Setup.
This program is available to LCD Monitor only.

1. Port Setup
a) Copy “UserPort.sys” file to “c:\WINNT\system32\drivers” folder
b) Run Userport.exe

c) Remove all default number
d) Add 300-3FF

e) Click Start button.
f) Click Exit button.

2. EDID Read & Write
1) Run WinEDID.exe

2) Edit Week of Manufacture, Year of Manufacture,
Serial Number
a) Input User Info Data
b) Click “Update” button
c) Click “ Write” button.

Set-up

Schematic

Scaler

Power & wafer

Inverter

Power