Wednesday 5 September 2018

Samsung HTz 210 – SMPS and amplifier schematic, no power, protection troubleshooting

How to troubleshoot power failure, power protection, power [SMPS] and main amplifier schematic - Samsung HTz210
Measures to be taken when the Protection Circuit operates

Operation of Power Block Protection Circuit
The Condition of Power Protection Active.
1. Voltage of SMPS’s PVDD (+34.5V, J3) is higher or lower than Standards.
Normal Condition Voltage Range: PVDD (+34.5V, J3): about +34.5V
2. Over-current occurs to AMP IC. (Over-output or Output short)
3. AMP IC’s temperature exceeds 150°C.
4. No supply voltage on GATE DRIVER
SMPS board & circuit diagram
Power Protection
* OTW: Active, IC’s inner temperature exceeds over 150°C.  (Under 2.7V, Protection Circuit wills Active)
* TAS5352 3rd PIN: Shout down  (Under 2.7V, Protection Circuit wills Active)
Total power failure troubleshooting
Check Amp in Power Protection

[check AMP Malfunction before disassembling Main Unit (Do NOT Insert AC-Cord in AC-Socket)]
Connector voltages
Amplifier schematic

LG 32LK610BPUA, LG 32LK610BBUA LCD TVs – How to upgrade the software, fault checking method