Saturday 9 September 2017

Tempo T903 Treadmill – How to enter to engineering mode – calibration - Running belt lubrication – Running belt adjustment

Engineering Mode
1) To enter Engineering Mode, press & hold the INCLINE UP “UP” and SPEED DOWN “DOWN” keys at the same time for 3-5 seconds until Engineering Menu appears on the display.
2) Use the INCLINE and SPEED UP and DOWN keys to select a parameter.
3) Press ENTER to enter a parameter setting.
4) Use the INCLINE and SPEED UP and DOWN keys to change the parameter.
5) Press the START key to save the change to the parameter.
6) Press and hold the STOP key to exit Engineering Mode and return to normal operation.
ENGINEERING MODE FUNCTIONS 
Mode Function Description
Eng 0 Display Test Start LED on
StopLED off
Any Keysdisplay on window
Hold “Stop” 3 sec back to “Engineering Menu”
Eng 1 Hardware Test Motor , Incline motor test
Eng 2 Auto Calibration To auto calibrate speed only.
Press ”Enter” first, then press “START”
Eng 3 Switch Function Use incline or speed to change “Demo” on or off
Use “Start” to select unit. 1—KM, 0—Mile
Eng 4 Information Accumulated Time and Distance
Hold “Start” 5 sec to reset
Remarks: Unit of Time is Hour.
Unit of Distance is KM or Mile based on your set.
LUBRICATING TREADMILL RUNNING BLT AND DECK
It is necessary to lubricate your treadmill running deck every six months or 150 miles (240 kilometers) to maintain optimal performance. Once the treadmill reaches 150 miles (240 kilometers), the console will dispHay the message “LUBE” or “LUBE BELT”. The treadmill will not operate while the message is showing. Hold ‘STOP’ for 5 seconds to suspend message for 5 miles.
Your treadmill came with a bottle of lubricant which can be used for two applications.
# Turn off the treadmill with the on/off switch, then unplug the power cord at the wall outlet.
# Loosen both the rear roller bolts. (for best results, place two removable marks on both sides of the frame and note roller position). Once the belt is loosened, take the bottle of lubricant and apply it to the entire top surface of the running deck. Tighten both rear roller bolts (matching up the marks for proper position) to original position. After you have applied lubricant, plug in the power cord, insert the safety key, start the treadmill and walk on the belt for two minutes to spread the lubricant.
# Lubricate the air shocks with Teflon based spray.
RESETTING LUBE MESSAGE
Once lubrication is complete, reset the console by pressing and holding ‘STOP’ and ‘SPEED +’ buttons for 5 seconds.
TENSIONING & CENTERING THE RUNNING BELT
If you can feel a slipping sensation when running on the treadmill, the running belt must be tightened. In most cases, the belt has stretched from use, causing the belt to slip. This is a normal and common adjustment. To eliminate this slipping, turn the treadmill off and tension both the rear roller bolts using the supplied Allen wrench, turning them 1/4 turn to the right as shown. Turn the treadmill on and check for slipping. Repeat if necessary, but never turn the roller bolts more than 1/4 turn at a time. Belt is properly tensioned when the slipping sensation is gone.
The running belt has been properly adjusted at the factory before it was shipped. At times the belt can move off-center during shipment. Before operating the treadmill, make sure the belt is centered and remains centered to maintain smooth operation.
If the running belt is too far to the right side: With the treadmill running at 1 mph, turn the left adjustment bolt counter-clockwise 1/4 turn at a time (using the supplied Allen wrench). Check the belt alignment. Allow belt to run a full cycle to gauge if more adjustment is needed. Repeat if necessary, until the belt remains centered during use.
If the running belt is too far to the left side: With the treadmill running at 1 mph, turn the right adjustment bolt counter-clockwise 1/4 turn at a time (using the supplied Allen wrench). Check the belt alignment. Allow belt to run a full cycle to gauge if more adjustment is needed. Repeat if necessary, until the belt remains centered during use.

LG 32LK610BPUA, LG 32LK610BBUA LCD TVs – How to upgrade the software, fault checking method

  Software update procedure USB (1) Insert the USB memory Stick to the USB port (2) Automatically detect the SW Version and show the bel...